ALL STAR Bleachers, Inc. offers a wide variety of press
boxes. There are many options available including, but
not limited to:
  • Interior and exterior finishes
  • Camera decks/filming platform
  • HVAC
  • Interior partitions
  • Floor Layouts to meet customer requirements

Shorecrest Preparatory School, St. Petersburg, FL
8' x 24' Pre-fabricated press box with camera deck

Side entry door with 6' landing and guardrail

Ocala Speedway, FL- 10' X 24'

Dixie County High School, Cross City, FL
Standard colors available upon request


Section 13126-MODULAR PRESS BOX

WORK SUMMARY:
Provide design, engineering, materials, freight, supervision required to
provide new Modular Press Box in accordance with the following
specifications.

QUALIFICATIONS:
Press box manufacturer must be a compnay specializing in modular
building construction with a minimum of five (5) years experience in manu-
facturing press boxes.

DESIGN LOADS:
Floor Live Load: 100 psf
Roof Load: 50 psf
Horizontal Wind: 31 psf (110 MPH)
Occupancy Load: __ persons

COMPONENTS:
Overall size of press box to be __ft.x__ft.

FLOOR SYSTEMS:
1. Bottom Board .040 asphalt impregnated bottom board
2. Insulation: 6" R-19 fiberglass batt insulation w/ vapor barrior
3. Joists: Unimast #60SJ16 6"x16 ga. Longitudinal steel floor
joists, 16" O.C.
4. Under Belly: 30 ga. Galvanized steel under belly
5. Decking: 26 ga. 1.0E steel deck (4 screws/33"length: S-12 Tek)
6. Flooring: 3/32" Armstrong vinyl tile flooring
7. Molding: 2-1/2" vinyl base cove molding

WALL SYSTEM:
1. Studs: Unimast #362SJ18 3-5/8" x 18 ga. steel studs, 16" O.C.
2. Wall Panels: 5/8" vinyl faced gypsum interior wall panels type x
firestop (Harvest)
3. Insulation: 3-1/2" R-11 fiberglass batt insulation w/ vapor barrior
4. Sheathing: 5/8" type x firestop gypsum exterior wall sheathing
5. Siding: 26 ga. vertical rib steel siding (McElroy Metals)

ROOF SYSTEM:
1. Roof Joists: Unimast #80SJ16 8" x 16 ga. steel roof joists 16" O.C.
2. Deck: 26 ga. 1. oe steel deck (4 screws/33"length:S-12 Tek)
3. Roofing: .060 polyester reinforced skip and spike resistant pvc
membrane (fully adhered)
4. Insulation: 6" R-19 fiberglass batt insulation w/ vapor barrier

5. Celing Panels: 5/8" dens deck fiberglass reinforced gypsum roof deck
sheathing (type x firestop)
6. Trim: Alcoa aluminum fascia and perforated soffit
7. Roof Hatch: Bilco #NB-50 roof hatch w/Alaco #460 aluminum
ladder
8. Roof Guardrail: 42" high guardrail system consisting of 1 5/8" o.d.
anodized aluminum tube top and bottom rail with
9 ga., 2" galvanized chain link mesh infill attached to
angle rail posts

DOORS:
1. Exterior: 36"x 80" Ceco "Imperial" insulated galvanized hollow metal door
with steel wrap around frames, hydraulic closer, weather strip,
aluminum threshold 10" lite, and keyed lever handled schlage locksets
(Paint to match siding).
2. Interior: 36"x 80"x 1-3/8" solid-core fruitwood birch pre-hung interior
door with matching wood jamb and casing, 1 3/8" pair mortised butt hinges
and passage lockset.

WINDOWS:
60"X 48" Wojan #M-85 Series commercial aluminum slider window with
5/8" insulated glass and thermal break extrusions with white frames.

SCORER'S TABLE:
18" deep x 3/4" thick AC plywood with 1 1/2"x 3" square edge. Top is
surfaced with .060 plastic laminate, Nevamar Golden Ash, 29" above floor
(Wisconsin Oak).

ELECTRICAL:
Electrical distribution panel w/ main disconnect-120/240V, 2-pole, 3-wire,
single phase, 100 amp capacity, square "D" Section #QO12M188 with 1-1/2"
conduit through wall. All branch circuit wiring per National Electrical Code,
encased in EMT thin wall conduit. Levitation 125V/20 amp spec. grade
heavy-duty duplex receptacles along back wall spaced at 9' intervals
Wiremold #2000 series electric plug strip over scorer's table. Lithonia
#TLB240 double tube florescent light fixtures with diffuser over scorer's table.
Three GE Zoneline (#AS22E009D5B) 3.5 KW heat/cool units, 9000 btu cool,
11.900 btu heat U/L listed.

WARRANTY:
Free from defect in material and workmanship in the course of
manufacturing for one (1) year.
*Above specifications are for fire rated construction. Wood frame
construction is also available.

Printer Friendly PagePrinter Friendly Page